$121.50(USA and Canada only)
Model Number
240D30-HS
480d25-hs
575D30-HS
Nominal AC Line Voltage
240
480
575
工作电压范围(Volts AC)
24–280
100–530
100–600
峰值重复电压最大
600
1000
1200
Off-State Leakage (mA) Maximum*
5 mA
10 mA
12 mA
Nominal Output Voltage Drop (RMS)
1.0 volts
Nominal Current Rating (Amps)
30**
25**
1 cycle Surge (Amps) Peak
610
I2t Rating t=8.3 (ms)
1550
Isolation Voltage (transient 4KV)
2,500VRMS
Dissipation (Nominal Watts/Amp)
1.0
Signal Pick-up Voltage
4VDC(允许32V)
Signal Drop-out Voltage
1 VDC
Nominal Signal Input Resistance (Ohms)
730
θja*** (°C/Watt)
2.2
Warranty
Lifetime
Notes:* Operating Frequency: 25 to 65 Hz (operates at 400 Hz with 6 times the offstate leakage).** Ambient temperature will affect the current rating. For details, see the Thermal Ratings charts in theSolid State Relays Data Sheet(form 0859).***θja = Thermal resistance junction to ambient. Maximum junction temperature is 110 °C.
A quick overview of Opto 22 solid-state relays (SSRs).
Opto 22 provides a full range of reliable solid-state relays (SSR). This data sheet includes descriptions, specifications, dimensional drawings, and application information.
This document is the Manufacturer's Declaration of Conformity for the products listed herein, in accordance with the rules, regulations and standards of the United Kingdom. The models cited have been tested to the essential requirements listed in the Standards section, and fully comply with the legislation as listed in UK Legislation section.
This document is a statement of compliance with the EU Directive 2015/863/EU, Restriction of Hazardous Substances (RoHS 3). This document lists Opto 22 products that comply with the substance restrictions of the RoHS 3 directive.
This document lists all Opto 22 part numbers that have the Underwriters Laboratory (UL) approval.