$385.00(USA and Canada only)
Input Range Sensitivity:SNAP-AILCSNAP-AILC-2
2 mV/V or 3 mV/V (Over range ± 2.2 mV or ± 3.3 mV)3 mV/V or 4 mV/V (Over range ± 3.3 mV or ± 4.4 mV)
Input Resistance
100 Megohms differential
Resolution: Analog Scale Points
>22 bits + sign (± 6,400,000 counts = ± 100% of scale)
Response Time,Data Freshness
See the following table
DC Reversal (Input)
0.015% (±1000 counts of reading @ 6,400,000 F.S.)
DC Common Mode Rejection
>-120 dB
AC Common Mode Rejection
>-120 dB @ 60 Hz
Maximum Survivable Input
± 15 volts across module load cell connector
Maximum Operating Common Mode Voltage
250 V
Accuracy (% Full Scale):OffsetGain
± 0.05% (= 3,200 counts out of 6,400,000, out of box)± 0.05% (= 3,200 counts out of 6,400,000, out of box)
Usable Resolution at Default Configuration (Fast)
38 nV - sign and 19 bits (±524,288 counts @ channel 2)At filter weight 64, settles to 99.9% of final reading in 3.9 s.
DRIFT:GainOffset
40 PPM / °C10 PPM / °C
Isolation: Optical
4000 V
Isolation: Transformer
1500 V
Rack Power Requirements
5.00 VDC to 5.20 VDC @ 120 mA
24V Bridge Supply:Input VoltageInput CurrentOutput Fault Current
24 VDC nominal (22 V min. to 30 V max.)40 mA for one load cell or 115 mA for four load cells124 mA typical (field fault—shorted bridge)
Ambient Temperature:OperatingStorage
-20 to 70 °C-40 to 85 °C
Humidity
5-95%, non-condensing
Wire size
22 to 14 AWG
Torque, hold-down screws
Not to exceed 1 in-lb (0.11 N-m)
Torque, connector screws
5.22 in-lb (0.59 N-m)
Agency Approvals
CE, RoHS, DFARS
Warranty
Lifetime
TheSNAP-AILCandSNAP-AILC-2load cell input modules each provide one channel of transformer and optically isolated analog-to-digital conversion for load cell inputs. These modules also provide isolated 10 VDC bridge excitation for up to four 350 ohm load cells.
This data sheet includes descriptions, specifications, and wiring and dimensional diagrams.
This document lists and describes all Opto 22 SNAP PAC System part numbers, including PAC Project software, SNAP PAC controllers, SNAP PAC brains, and SNAP I/O modules of all kinds. SNAP PAC mounting racks and SNAP power supplies are also listed.
This document is a statement of compliance with the EU Directive 2015/863/EU, Restriction of Hazardous Substances (RoHS 3). This document lists Opto 22 products that comply with the substance restrictions of the RoHS 3 directive.
This document is the Manufacturer's Declaration for the listed products as mentioned in the attachment - to which this confirmation refers - that they are in accordance with the mentioned European, international and/or national standards and regulations.